Developer Powder & Fixer Powder for manual processing.
It can be used with various medical x-ray films.
low fog, powerful contrast, sharp sensitivity and high resolution ratio.
Packing methods:
1. 2.64gallons/bag, 10 bags/carton, each bag to prepare 10L working solution.
2. 5.284gallons/bag, 5 bags/carton, each bag to prepare 20L working solution
* Special specifications available according to customers' requirements.
Handling:
In manual processing, the film should be developed with temperature (18~24 ºC) for 5~6 minutes, fixed in 5-8 minutes, washed for 10-30 minutes and dried.
Storage
Store in a cool, dry place (The suitable temperature is 5-30 celsus degrees ).
Keep it away from dampness, high temperature, direct sunlight, any bad effective gases.
Quality guarantee two years, but be sure the package is good sealed.
* The compounded developing and fixing liquid shall be used after 24 hours immobility and kept with cover.
Product |
Developer powder for manual processing |
Fixer powder for manual processing |